PROBLEM: Chromium levels in San Bernardino County’s water source averaged between 18 – 22 µg/L, exceeding the MCL standard of 10 µg/L. RESULT: The hexavalent chromium concentration was reduced by the pilot unit to non-detectable levels. San Bernardino_CA
Category: Pilot Studies
Mountain Water & Sanitation District Conifer, Colorado
PROBLEM: Feed concentration of uranium in water source was as high as 370.0 ppb, exceeding MCL standard of 30 ppb. RESULTS: Pilot unit reduced uranium levels to an average of 1.2 ppb. Mountain_Water_Conifer_CO
City of Lawrenceville, Georgia
PROBLEM: Uranium levels in water source were as high as 241 pCi/L, exceeding the MCL standard of 20 pCi/L. RESULTS: Pilot unit reduced uranium levels to an average of 0.7 pCi/L Lawrenceville_Pilot
City of Grand Island, Nebraska
PROBLEM: Uranium and gross alpha levels in water source were as high as 31.0 µg/L for uranium, and 45.0 pCi/L for gross alpha, both exceeding the MCL standard of 30 µg/L for radium and 15 pCi/L for gross alpha. RESULTS: Pilot unit reduced uranium levels to an average of 0.2 µg/L and gross alpha levels to an average of 3.2 pCi/L. Grand_Island_NE
Schurz Elementary School – Schurz, Nevada
PROBLEM: Uranium, arsenic and gross alpha levels in water source were as high as 99.9 µg/L for uranium, 13.5 µg/L for arsenic and 57.0 pCi/L for gross alpha; all exceeding MCL standards. RESULTS: Pilot unit reduced uranium levels to an average of 0.2 µg/L, arsenic levels to an average of 1.2µg/L, and gross alpha levels to 2.6 pCi/L. Schurz_NV
Borough of Hopewell, New Jersey
PROBLEM: Uranium, radium and gross alpha levels in water source were as high as 43.7 pCi/L for uranium, 13.6 pCi/L for radium and 85.6 pCi/L for gross alpha; all exceeding MCL standards. RESULTS: Pilot unit reduced uranium levels to an average of 2.6 pCi/L, radium levels to an average of 1.3 pCi/L, and gross alpha levels to 5.5 pCi/L. Hopewell_ Pilot_Study_Report_CONDENSED
City of Hastings, Nebraska – ARS Well No. 27
PROBLEM: Uranium and gross alpha levels in water source were as high as 23.0 µg/L for uranium, and 20.2 pCi/L for gross alpha, exceeding the MCL standard of 15 pCi/L for gross alpha. RESULTS: Pilot unit reduced uranium levels to 0.0 µg/L throughout the study, and gross alpha levels to an average of 2.4 pCi/L. Hastings_ Pilot_Study_Report_FINALCondensed29Jan18
Cortland, Illinois
PROBLEM: Radium levels in water source averaged 12.4 pCi/L, exceeding MCL standard of 5 pCi/L. RESULTS: Concentration of radium as high as 15 pCi/L was reduced by pilot unit to an average of 3.5 pCi/L. Cortland
Richland Special Utility District – Richland Springs, Texas
PROBLEM: Feed concentration of radium in water source was as high as 44.7 pCi/L, exceeding MCL standard of 5 pCi/L. RESULTS: Pilot unit reduced radium levels to an average of 0.9 pCi/L. RichlandSps
Gilbert-Summit Rural Water District – Gilbert, South Carolina
PROBLEM: Radium levels in water source averaged 8 pCi/L, exceeding MCL standard of 5 pCi/L. RESULTS: Concentration of radium as high as 9.5 pCi/L was reduced by pilot unit to an average of 0.5 pCi/L. Gilbert_Summit